A nighttime street scene featuring a row of lit white colonial-style houses with wrap-around porches, flanked by oak trees draped in Spanish moss.

Mini Split Installation in Bastrop, LA

Tell us about the job

Takes about a minute. No obligation.

New system or replacementMini-splitMorehouse Parish, LA
Step 1 of 2

What ZIP code is the job in?

Morehouse Parish saw 113 severe weather events between 2015 and 2024. Most of that was wind, 76 events, with 17 hail events and 13 tornadoes mixed in. A mini split's outdoor unit sits outside through all of it, exposed to wind-driven debris and hail in a way a furnace or a water heater tucked indoors never is. Power cuts follow the same storms. Nearly half of Louisiana households went at least a day without power in 2024. That matters more here than in places with mild weather and steady grids, because it's both ends at once: the unit outside taking the weather, and the power behind it going out right when you need heat or cooling most.

5 months
November through March, your system heats
5 months
May through September, it cools
37°F
the average winter night it heats against
92°F
the average summer afternoon it cools against
Isometric illustration of a cutaway single-story house with a dark shingled roof, showing two wall-mounted indoor air conditioning units connected by lines to an outdoor condenser unit on a pad beside the building.
Your system heats November through March and cools May through September.

NOAA nClimDiv, 1991–2020 normals

Five months of cooling a year, with afternoon highs averaging 92°F and a dew point near 69°F.

A mini split installed here runs long hours against heavy, muggy air most summers, so sizing it right matters more than finding the lowest price.

Most homes here already run on electricity, and a mini split fits right into that

59% of homes heat with electricity
Cooling runs May through September
Summer afternoons average 92°F
Get it in before MayCooling starts in May here. April is the month to have it done.

Morehouse Parish falls under climate zone 3A, and any mini split installed here has to meet the federal minimum for that kind of system. For a ductless heat pump manufactured from 2023 on, that means pulling at least 14.3 Btu of cooling from every watt-hour it uses over the summer, and delivering at least 7.5 Btu of heat per watt-hour over the winter. Those numbers set the floor, not a target to aim for. A contractor sizing a system for this parish is already working within that limit, so the real comparison between units is how far above it they run. On top of meeting that standard, a qualifying system may also open up a federal tax credit worth looking into before you settle on equipment.

Plan the install around the power going out

Where the outdoor unit goes and how it's mounted is part of the install, not an afterthought. A contractor can set it where flying debris is less likely to reach it and brace it against wind. Worth asking about a system that can run heat or cooling through a power cut too, since the storms that knock down lines here are the same ones that make you need the system most.

Find a contractor
A white outdoor air conditioner condenser unit mounted on metal wall brackets against gray horizontal siding, with a blue sky and white clouds behind it.

Five months a year, every year

Five months of cooling a year adds up to a lot of hours on the unit you choose. Get the sizing wrong and it shows: a system too small runs flat out all summer and still can't keep up, one too large cycles on and off and leaves the air damp. This is where the installer's load calculation matters more than the brand on the box. Ask what size they're recommending and why, based on your house, not a price point.

Sizing comes from a room by room calculation

A mini split is sized by working out how much heat moves through the walls, windows and roof of the space it's serving, not by matching the square footage on a chart. The calculation accounts for insulation, window area and orientation, how many exterior walls a room has, and what's generating heat inside it. Two rooms the same size can need different sized heads once you account for those things.

Wrong either way costs you comfort

A unit sized too big for the space cools the air fast and shuts off before it pulls the moisture out, so the room feels cold and damp at once. One sized too small runs constantly and never quite catches up on the hottest afternoons. Getting the size right the first time avoids both, and it's not something you can fix later by adjusting the thermostat.

If you're replacing a window unit or a central system, someone has to deal with what's already there. A window unit just comes out of the frame, and the opening gets sealed up properly so it's not leaking air afterward. A central system is more involved. The old indoor coil, the furnace or air handler, and the outdoor condenser all get disconnected and hauled away, and the refrigerant in the lines has to be recovered first, not vented, because venting it is illegal and the gas itself is harmful. If ductwork was only ever serving that old central system and the mini split doesn't use it, the ducts usually just get left alone or sealed off rather than torn out. Any electrical circuit dedicated to the old equipment either gets reused for the new units or capped off safely. None of this is complicated, but it's work, and it's worth asking upfront who handles the removal and disposal so it isn't a surprise on install day.

Install day starts with the outdoor unit, and where it sits gets decided before anything is mounted. The installer runs refrigerant lines and a condensate drain from that spot to each indoor head, usually through a small hole drilled in the wall rather than an existing opening. Each indoor head gets mounted on a bracket, leveled, and connected to its own line set and a wire for communication with the outdoor unit. Once everything's connected, the lines get pulled down to a vacuum to clear out air and moisture before refrigerant is ever released into them, because either one left in the system will cause problems later. The installer checks for leaks at every joint before closing things up, then runs the system through both heat and cooling to confirm each head is responding right and the refrigerant charge is correct. The last step is usually the quietest part, going head by head to show you how the controls work.